Page
Set Descending Direction
  1. There are more products that fulfill technical criteria for your country available through vendors from abroad.
  2. Aquarea heat pump WH-MXC16H9E8

    Aquarea T-CAP Monobloc H Generation Three Phase. R410A refrigerant.
    Add to List
    Energy source
    Electricity
    Heating capacity
    16.00 kW
    Cooling capacity
    12.00 kW
    EU energy label
    A+++
    Coefficient of performance (COP)
    4.28 COP
  3. Vitocal 200-S type AWB-M 201.D16

    Split type heat pump for heating with integrated electro heater
    Add to List
    Energy source
    Electricity
    Heating capacity
    9.00 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Coefficient of performance (COP)
    4.54 COP
  4. ESTIA RUA-CP2101H8

    This ESTIA range is ideal for a large heating and cooling applications. This flexible solution allows up to 4 units to be connected in master/slave group control.
    Add to List
    Energy source
    Electricity
    Heating capacity
    21.10 kW
    Cooling capacity
    18.60 kW
    EU energy label
    A+
    Coefficient of performance (COP)
    4.10 COP
  5. LIK 8TES

    Heating heat pump for indoor installation with integrated control WPM 2007 plus. The control unit integrated in a brown-red design panel can also be used as a wired remote control by means of a wall mounting set (special accessory MS PGD). The integrated air duct allows the corner or wall installation with air ducts on the intake and exhaust side. Sound-optimized by low-noise axial fan and vibration-decoupled compressor. High performance figures due to an evaporator optimized for heating operation and energy-efficient defrost by circulation reversal. Universal design with optional DHW heating and flexible expansion options for: bivalent or bivalent regenerative mode Distribution systems with unmixed and mixed heating circuits Built-in pipe heater (2/4/6 kW) With an outside temperature of -10 ° C, a maximum flow temperature of 53 ° C can be achieved. Soft starter, flow and return sensor integrated; Outdoor sensor (standard NTC-2) included.
    Add to List
    Energy source
    Electricity
    Heating capacity
    6.60 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Coefficient of performance (COP)
    3.50 COP
  6. MAXA i-HWAK V4 06

    Chiller and inverter air/water heat pumps with axial fans
    Add to List
    Energy source
    Electricity
    Heating capacity
    6.57 kW
    Cooling capacity
    6.87 kW
    EU energy label
    A++
    Coefficient of performance (COP)
    4.47 COP
  7. Hitachi Yutaki S Combi RWD-6.0NWE-200S/RAS-6WHNPE

    Heat pumps series Hitachi Yutaki S Combi are ideally suited for compact houses, where there is no possibility to install external tank for hot water. There is a stainless steel tank built-in this line of heat pumps and has a volume of 200 l or 260 l. Equipment is suitable for heating, hot water or air conditioning.
    Add to List
    Energy source
    Electricity
    Heating capacity
    17.80 kW
    Cooling capacity
    17.50 kW
    EU energy label
    A++
    Coefficient of performance (COP)
    4.57 COP
  8. 38AW 090H7

    Reversible XP Energy air-to-water split system heat pumps with built-in inverter technology, designed for residential and light commercial applications.
    Add to List
    Energy source
    Electricity
    Heating capacity
    9.10 kW
    Cooling capacity
    6.00 kW
    EU energy label
    A+
    Coefficient of performance (COP)
    4.20 COP
  9. PBM-i+10

    Inverter air-to-water monobloc heat pumps Compressor with modulation from 30 to 130%, R410A gas Hot water up to 60°C, operation in summer with outdoor air temperature up to 43°C
    Add to List
    Energy source
    Electricity
    Heating capacity
    9.00 kW
    Cooling capacity
    8.00 kW
    EU energy label
    A++
    Coefficient of performance (COP)
    4.02 COP
  10. Hitachi Yutaki M RASM-5VNE

    Heat pumps monoblock series Hitachi Yutaki M can work with low temperature radiators, fan coils or underfloor heating. Series is suitable for heating, hot water or air conditioning. All structure of the heat pump is located in the outdoor unit, which reduces the cost of the system
    Add to List
    Energy source
    Electricity
    Heating capacity
    16.70 kW
    Cooling capacity
    16.00 kW
    EU energy label
    A++
    Coefficient of performance (COP)
    4.71 COP
  11. Logatherm WPL 7 AR B

    Air-to-water heat pump heating reversible type Logatherm. The temperature in the direct pipeline to 62 degrees Celsius. The heat pump consists of an external and internal units. Designed for heating, hot water and active cooling. It is used for R410A.
    Add to List
    Energy source
    Electricity
    Heating capacity
    7.00 kW
    Cooling capacity
    6.71 kW
    EU energy label
    A++
    Coefficient of performance (COP)
    4.84 COP
  12. HN1639.NK3 + HU123.U33

    Therma V it is highly efficient water heating system and consists of 2 blocks: external and internal (hydraulic module). Nominal Capacity - 12.0 kW
    Add to List
    Energy source
    Electricity
    Heating capacity
    12.00 kW
    Cooling capacity
    10.40 kW
    EU energy label
    A++
    Coefficient of performance (COP)
    4.55 COP
  13. LI 9TU

    Heating heat pump for indoor installation with integrated control WPM EconPlus. Sound-optimized by low-speed EC-3D radial fan, enclosed compressor chamber and freely oscillating compressor base plate for structure-borne sound decoupling. High performance figures due to high-performance evaporator, electronic expansion valve and fulfillment of the requirements according to EN 14511 for larger volume flows on the heat utilization side. High operational safety through sensory monitoring of the refrigeration circuit with demand-dependent defrosting; Integrated heat quantity counting (display of the calculated heat quantity for heating and hot water preparation at the heat pump manager WPM EconPlus). The integrated air duct with 90 ° deflection allows a direct corner installation without air ducts or a wall installation with air ducts on the outlet side. Variable installation by air intake from the rear, flexible air outlet to the right, left or top and the possibility to move the hydraulic connections from right to left. The control unit integrated in a brown-red design panel can also be used as a wired remote control by means of a wall mounting set (special accessory MS PGD). Universal design for low-temperature heating systems with flexible expansion options for: Room temperature control via Smart-RTC (optional) bivalent or bivalent regenerative mode Distribution systems with unmixed and mixed heating circuits With an outdoor temperature of -10 ° C, a maximum flow temperature of 56 ° C can be achieved. Soft starter, flow and return sensor integrated; Outdoor sensor (standard NTC-2) included.
    Add to List
    Energy source
    Electricity
    Heating capacity
    6.80 kW
    Cooling capacity
    0.00 kW
    EU energy label
    A++
    Coefficient of performance (COP)
    3.90 COP
Page