Cooling

Page
Set Descending Direction
  1. There are more products that fulfill technical criteria for your country available through vendors from abroad.
  2. Bitzer 4PCS-15.2

    With the series C1 to C8 BITZER offers compressors for HFC and HCFC refrigerants, that meet the demanding requirements of modern refrigeration plants: Universally applicable One compressor version for R134a, R404A, R507A, R407C and R22 ● for air-conditioning ● for medium and low temperature applications
    Add to List
    Cooling capacity
    20.65 kW
    Rated power
    7.36 kW
    Refrigerant
    R-134a
    Energy label (energy efficiency class)
    C
    Output temperature
    <0 Celsius
    Coefficient of performance (COP)
    2.80 COP
  3. LWT2600

    he HYDROCIATTURBO LWT has compact dimensions. The footprint and the overall volume of the device have been optimised to enable them to be easily integrated into any machine room Quick, easy maintenance > Excellent accessibility Quick access to all refrigeration and electrical components to facilitate maintenance operations Quick installation > Easy connections The ease of installation of the HYDROCIATTURBO LWT really sets it apart - the surface area required is limited to the dimensions of the appliance - simple three-phase 400V wiring, with no neutral, thanks to the control transformer included
    Add to List
    Cooling capacity
    1007.00 kW
    Rated power
    537.00 kW
    Refrigerant
    R-134a
    Energy label (energy efficiency class)
    A
    Output temperature
    above 7 Celsius
    Coefficient of performance (COP)
    1.88 COP
  4. LWT2300

    he HYDROCIATTURBO LWT has compact dimensions. The footprint and the overall volume of the device have been optimised to enable them to be easily integrated into any machine room Quick, easy maintenance > Excellent accessibility Quick access to all refrigeration and electrical components to facilitate maintenance operations Quick installation > Easy connections The ease of installation of the HYDROCIATTURBO LWT really sets it apart - the surface area required is limited to the dimensions of the appliance - simple three-phase 400V wiring, with no neutral, thanks to the control transformer included
    Add to List
    Cooling capacity
    880.00 kW
    Rated power
    457.00 kW
    Refrigerant
    R-134a
    Energy label (energy efficiency class)
    A
    Output temperature
    above 7 Celsius
    Coefficient of performance (COP)
    1.93 COP
  5. LWT2100

    he HYDROCIATTURBO LWT has compact dimensions. The footprint and the overall volume of the device have been optimised to enable them to be easily integrated into any machine room Quick, easy maintenance > Excellent accessibility Quick access to all refrigeration and electrical components to facilitate maintenance operations Quick installation > Easy connections The ease of installation of the HYDROCIATTURBO LWT really sets it apart - the surface area required is limited to the dimensions of the appliance - simple three-phase 400V wiring, with no neutral, thanks to the control transformer included
    Add to List
    Cooling capacity
    791.00 kW
    Rated power
    230.00 kW
    Refrigerant
    R-134a
    Energy label (energy efficiency class)
    A
    Output temperature
    above 7 Celsius
    Coefficient of performance (COP)
    3.44 COP
  6. LWT1900

    he HYDROCIATTURBO LWT has compact dimensions. The footprint and the overall volume of the device have been optimised to enable them to be easily integrated into any machine room Quick, easy maintenance > Excellent accessibility Quick access to all refrigeration and electrical components to facilitate maintenance operations Quick installation > Easy connections The ease of installation of the HYDROCIATTURBO LWT really sets it apart - the surface area required is limited to the dimensions of the appliance - simple three-phase 400V wiring, with no neutral, thanks to the control transformer included
    Add to List
    Cooling capacity
    717.00 kW
    Rated power
    201.00 kW
    Refrigerant
    R-134a
    Energy label (energy efficiency class)
    A
    Output temperature
    above 7 Celsius
    Coefficient of performance (COP)
    3.57 COP
  7. LWT1400

    he HYDROCIATTURBO LWT has compact dimensions. The footprint and the overall volume of the device have been optimised to enable them to be easily integrated into any machine room Quick, easy maintenance > Excellent accessibility Quick access to all refrigeration and electrical components to facilitate maintenance operations Quick installation > Easy connections The ease of installation of the HYDROCIATTURBO LWT really sets it apart - the surface area required is limited to the dimensions of the appliance - simple three-phase 400V wiring, with no neutral, thanks to the control transformer included
    Add to List
    Cooling capacity
    550.00 kW
    Rated power
    140.00 kW
    Refrigerant
    R-134a
    Energy label (energy efficiency class)
    A
    Output temperature
    above 7 Celsius
    Coefficient of performance (COP)
    3.93 COP
  8. EWAD-TZSSB/SLB-160

    Air cooled screw inverter chiller, standard efficiency, standard sound
    Add to List
    Cooling capacity
    169.00 kW
    Rated power
    56.00 kW
    Refrigerant
    R-134a
    Energy label (energy efficiency class)
    A+++
    Output temperature
    <0 Celsius
    Coefficient of performance (COP)
    2.99 COP
  9. EWAD-CFXS/XL-640

    Air cooled screw chiller with free cooling, high efficiency, standard sound
    Add to List
    Cooling capacity
    640.00 kW
    Rated power
    257.00 kW
    Refrigerant
    R-134a
    Energy label (energy efficiency class)
    A+++
    Output temperature
    <0 Celsius
    Coefficient of performance (COP)
    2.49 COP
  10. EWWD-VZSS-600

    Water cooled screw inverter chiller, standard efficiency, standard sound.
    Add to List
    Cooling capacity
    610.00 kW
    Rated power
    110.00 kW
    Refrigerant
    R-134a
    Energy label (energy efficiency class)
    A+++
    Output temperature
    <0 Celsius
    Coefficient of performance (COP)
    5.50 COP
  11. EWWD-VZXS-450

    Water cooled screw inverter chiller, standard efficiency, standard sound.
    Add to List
    Cooling capacity
    449.00 kW
    Rated power
    81.00 kW
    Refrigerant
    R-134a
    Energy label (energy efficiency class)
    A+++
    Output temperature
    <0 Celsius
    Coefficient of performance (COP)
    5.53 COP
  12. Daikin EUW40

    This manual applies to water-cooled chillers of the EUW-HZ series condenser from Daikin. These chillers are designed for internal installations and for recreation cooling and / or water systems.
    Add to List
    Cooling capacity
    112.00 kW
    Rated power
    32.00 kW
    Refrigerant
    R-134a
    Energy label (energy efficiency class)
    C
    Output temperature
    above 7 Celsius
    Coefficient of performance (COP)
    3.50 COP
  13. Daikin EUW32

    This manual applies to water-cooled chillers of the EUW-HZ series condenser from Daikin. These chillers are designed for internal installations and for recreation cooling and / or water systems.
    Add to List
    Cooling capacity
    86.00 kW
    Rated power
    24.20 kW
    Refrigerant
    R-134a
    Energy label (energy efficiency class)
    C
    Output temperature
    above 7 Celsius
    Coefficient of performance (COP)
    3.55 COP
Page
Set Descending Direction